Monarch 900 Door Operator Troubleshooting 2

Fault Display Er06

Fault Description: Acceleration Overvoltage

Fault Causes:
1. Input voltage too high;
2. Braking resistor too large;
3. Acceleration curve too steep.

Solutions:
1. Adjust input voltage;
2. Select appropriate braking resistor;
3. Adjust curve parameters.

 

 

Fault Display Er07

Fault Description: Constant Speed ​​Overvoltage

Fault Causes:
1. Input voltage too high;
2. Braking resistor too large;
3. Deceleration curve too steep.

Solutions:
1. Adjust input voltage;
2. Select appropriate braking resistor;
3. Adjust curve parameters.

 

 

Fault Display Er09

Fault Description: Undervoltage Protection

Fault Causes:
1. Input power momentarily stops;
2. Input voltage too low;
3. Control board malfunction. Troubleshooting Methods:

1. Rule out external power supply issues.
2. Contact your distributor or manufacturer.

Note: Automatic reset after voltage returns to normal.

 

 

Fault Display: Er10

Fault Description: System overload

Fault Causes:

1. No obstructions in the elevator door guide rails.
2. Excessive load.

Troubleshooting Methods:

1. Inspect the elevator door guide rails.

2. Reduce the load.