Monarch 900 Door Operator Troubleshooting 1

Fault Display Er02

Fault Description: Acceleration Overcurrent

Fault Causes

1. Main circuit output grounding or short circuit
2. Motor parameter tuning issues
3. Overload.

Solutions
1. Eliminate external issues such as wiring problems
2. Motor parameter tuning
3. Reduce sudden load.


Fault Display Er03

Fault Description: Deceleration Overcurrent

Fault Causes

1. Main circuit output grounding or short circuit
2. Motor parameter tuning issues
3. Overload
4. Deceleration curve too steep.

Solutions
1. Eliminate external issues such as wiring problems
2. Motor parameter tuning
3. Reduce sudden load
4. Adjust curve parameters.


Fault Display Er04

Fault Description: Constant Speed ​​Overcurrent

Fault Causes

1. Main circuit output grounding or short circuit
2. Motor parameter tuning issues
3. Overload
4. High interference from rotary encoder.

Troubleshooting methods: 1. Eliminate external problems such as wiring issues; 2. Tune motor parameters; 3. Reduce sudden loads; 4. Select a suitable rotary encoder and use shielded rotary encoder cables.